Confined Spaces Installation

For installations in occupied commercial and residential structures – or in passenger rail or pedestrian tunnels – there is a stringent requirement for duct and fiber cable products to be manufactured using Low Smoke Zero Halogen (LSZH) rated materials.

Applications
INSTALLING LSZH IN TUNNEL APPLICATIONS

Use the proper pulling hardware and do not exceed the maximum tensile pull rating of the ducts. Use swivels – attached to each duct and, the lead pull line – and wire rope slings (bridle) for maximum pulling clearance in the conduit and reduce twisting of the ducts. When placing different size ducts simultaneously, the pull tension maximum is limited to the duct with lowest published pull tension maximum. Note that when air jetting in cables, LSZH duct products may have lower than normal jetting pressure maximums due to the nature of the LSZH material.

PLACING OF MICRODUCT UNDER RAISED FLOORING OR IN CEILINGS

When placingPplenum in raised-floor environments, to reduce undulations, it is critical to provide frequent support for the bundle or bundles. FuturePath 7-way  needs support approximately every meter, and larger bundles about every 1.5 meters. FuturePath can also be placed into existing raceways or trays.

Want a better connection with Dura-Line?

Ask a question or email us a comment! We're happy to supply additional information and explore how we can be of service to you.

Contact Us

Want a better connection with Dura-Line?

Ask a question or email us a comment! We're happy to supply additional information and explore how we can be of service to you.

Contact Us